多功能搅拌车皮带秤的校准方法:将速度控制器上的“自动/手动”开关设置到手动位置,将速度调节到小电位器,打开主机和速度控制器的电源。15分钟后,启动皮带秤,调节速度控制器上的速度,让电位器使皮带运转(转速400-500转/分),根据需要测试零点。按F3键将光标移动到要校准的K值的前面,然后按F5键,在已知重量(累计重量大于100KG)的跑带上放置一些沙袋。
Calibration method of multifunctional mixer belt scale: set the "auto / manual" switch on the speed controller to the manual position, adjust the speed to the small potentiometer, and turn on the power supply of the host and speed controller. After 15 minutes, start the belt scale, adjust the speed on the speed controller, let the potentiometer make the belt run (speed 400-500 RPM), and test the zero point as required. Press F3 to move the cursor to the front of the K value to be calibrated, and then press F5 to place some sandbags on the running belt with known weight (cumulative weight greater than 100kg).
从皮带上完成代码或沙袋后,按Enter键。此时,以流量显示重量或沙袋的累积值,然后将重量或沙袋的重量发送到K值。道路的K值由微型计算机确定。计算新的K值并以相同的方式校准2-3次,直到累积流量等于实际流量。其他道路标记方法与上述相同。
After completing the code or sandbag from the belt, press enter. At this time, the cumulative value of weight or sandbag is displayed by flow, and then the weight or sandbag weight is sent to K value. The K value of the road is determined by a microcomputer. Calculate the new K value and calibrate 2-3 times in the same way until the cumulative flow equals the actual flow. Other road marking methods are the same as above.
校准方法在多功能搅拌车中有两种校准螺旋电子秤的方法:将速度控制器上的“自动/手动”开关置于手动位置,将给定电位器的速度调较小,并且螺旋电子秤启动。内部的水泥是干净的,然后根据零测量方法测量零点。
Calibration methods there are two methods to calibrate the spiral electronic scale in the multi-function mixer: put the "auto / manual" switch on the speed controller in the manual position, adjust the speed of the given potentiometer to a smaller value, and start the spiral electronic scale. The cement inside is clean and then zero is measured according to the zero measurement method.
按F3键将光标移动到第七路K值的前面,按F5键调节送料器速度控制的速度,让电位器旋钮卸下,同时拧紧螺丝电子秤在排出口排出,水稳定。混合站的混合带完成后,按Enter键,然后将物料的实际重量发送到K值。按Enter确认。这是K值自动生成一个新的K值,它以相同的方式校准。直到累计重量等于实际重量,校准完成。
Press the F3 key to move the cursor to the front of the seventh K value, press the F5 key to adjust the speed of the feeder speed control, so that the potentiometer knob can be removed, at the same time, tighten the screw, and the electronic scale discharges at the discharge outlet, so that the water is stable. When the mixing belt of the mixing station is finished, press enter, and then send the actual weight of the material to K value. Press enter to confirm. This is the K value that automatically generates a new K value, which is calibrated in the same way. The calibration is completed until the cumulative weight equals the actual weight.
多功能搅拌车水的校准方法:由于系统采用水表,即高精度电子测量水表,水的校准简单。重要的是将对应于每千克水的水表的脉冲量发送到第九道路的K值。
Multi function mixer water calibration method: because the system uses water meter, that is, high-precision professional electronic measuring water meter, water calibration is simple. It is important to send the pulse quantity of the water meter corresponding to each kilogram of water to the K value of the ninth road.